Possible faults, causes and elimination methods of knife gate valve:
possible failures | Cause of failure | Elimination method |
Packing leakage | 1. The packing gland is not pressed tightly 2. The filler fails due to long-term use or improper storage | 1. Tighten the nut evenly to compress the packing 2. Replace the packing |
Leakage between sealing surfaces | 1. There is dirt and debris attached to the sealing surface 2. Damaged sealing surface | 1. Clean the dirt and sundries 2. Rework, trim or replace |
Leakage at the connection between the valve body and the bonnet | 1. Uneven tightening of connecting bolts 2. The flange sealing surface is damaged | 1. Tighten evenly 2. Refinish |
The handwheel is inflexible or the gate cannot be opened and closed | 1. The packing is pressed too tightly 2. The stem nut is damaged 3. The thread of the stem nut is severely worn or broken 4. Stem bending | 1. Properly loosen the nut on the packing pressure plate 2. Disassemble and trim threads and remove dirt and debris 3. Replace the stem nut 4. Correct the valve stem |
2022.01
Knife gate valve is a special kind of gate valve. Although this kind of valve has been introduced a lot before, I found that some friends st...
2021.10
At present, the knife gate valve sealing ring industry on the market is showing an upward trend, keeping up with market trends. With the con...
2022.11
? ? slide gate valveIt is a valve in which the gate and valve seat are always in close contact and sealed. The principle is that the gate ha...
Contact Us
Tel: 0577-67962833
Sales: 0577-67371666
Address: Wuxing Industrial Zone, Oubei Town, Yongjia County, Wenzhou City, Zhejiang Province, China
E-mail: [email protected]